First Alert Keypad Manual

Manual # M08-0278-008 Manual # M08-0278-008 www.FirstAlert.com. All First Alert® safes are designed and built using the highest manufacturing. The top of the keypad on the front of the safe will blink twice, the keypad backlight will flash once and you will.

Download Installation manual of First Alert FA215KP Keypad for Free or View it Online on All-Guides.com.

  • View and Download First Alert FA260RF installation instructions manual online. FA260RF transceiver pdf manual download.
  • First Alert FA570KP Manuals & User Guides. User Manuals, Guides and Specifications for your First Alert FA570KP Keypad. Database contains 1 First Alert FA570KP Manuals (available for free online viewing or downloading in PDF): Installation and setup manual.
  • First Alert FA-148C-CN manual: Functions of the Keypads. Burglary sensors, guarding protected doors, windows, and other perimeter protection points,.

Brand: First Alert

Category: Keypad

Type: Installation manual

Model: First Alert FA215KP , First Alert FA260KP , First Alert FA560KP

Pages: 2

REMOTE KEYPADS
INSTALLATION GUIDE
FA215KP
Alert
FA260KP
FA560KP
Backlit DisplayNOYES (See Note 1)YES (See Note 1)
Built-in SounderPiezoSpeakerSpeaker
FA110C*YESYESNO
FA142C*YESYESSee Note 2
FA162C*YESYESSee Note 2
FA1340C**YESYESSee Note 2
FA2000C*YESYESSee Note 2
The FA560KP must be used to program the FA142C, FA148C, FA162C, FA1220CV, FA1340C, FA1600C/CA/CB, & FA2000C controls.
*Use the non-addressable mode with these controls (set to address 31).
**Use the addressable mode with these controls (addresses 00-30).
Notes1.Permanent display backlighting is an option on some controls (see the control's instructions for details).
2.The FA560KP is required for certain advanced user functions (see the control's instructions for details).
3.Use the FA560KP with the red color insert (provided for fire installations) as required by local authority having jurisdiction
Remote Keypads and are intended for use with the controls
listed in table above. Addresses are set via the keypad keys
(no DIP switches). See the table above for valid addresses.
The keys on the keypads are continuously backlit for
KEYPAD DISPLAYS AND LEDS
The keypads have the following features of the display:
Fixed
Display
Alpha
2-digit
Identifier
Descriptors
First
FA260KPXX
The following table shows the LEDs and their functions:
RedLights when the system is armed in any mode
GreenLights when the system is 'ready' to be armed.
The keypads also feature function keys, see table below.
These keys may be programmed for panic alarms or other
special functions such as macros. See the control's
instructions for details. The FA215KP uses the key pairs
Function keys must be held down for at least 2
immediately.
A ([1] & [*])[1] & [*]
C ([3] & [#])[3] & [#]
The keypads can be surface mounted directly to a drywall, or to
by pushing down two 'snaps.'
through the
3.
Mount the case back

First Alert 560 Keypad Manual

from the keypad’s terminal block to the
terminal block on the control board. Wire functions are
marked next to terminals. Labels are as follows: DI Data
In to Control Panel, - Ground, + Aux. Power Plus, DO Data
Out of Control Panel. See the control panel’s Installation
5.
Manual
Re-attach the keypad to its case back

First Alert Keypad Manual

6.
Remove the clear protective film from the LCD display.
the 2 'Snaps' along keypad's
apart

Related Products for First Alert FA215KP

Related Manuals for First Alert FA215KP

First Alert FA215KP: Frequently viewed Manuals

Download Installation and setup manual of First Alert FA220KP Keypad for Free or View it Online on All-Guides.com.

Brand: First Alert

Category: Keypad

Type: Installation and setup manual

Model: First Alert FA220KP , First Alert FA270KP , First Alert FA570KP

Pages: 2

R
REMOTE KEYPADS
INSTALLATION AND SETUP GUIDE
FA220KP
FA270KP
FA570KP
Backlit Display NO YES (See Note 1) YES (See Note 1)
Built-in Sounder Piezo-electric Speaker Speaker
First Alert Pro Controls
Fixed-Word
Fixed-Word
2-Line Alpha
FA168CPS**, FA1220CV**, FA1340C**,
FA1600C/CA/CB**, FA1660C**,
NO NO YES
The FA570KP must be used to program the FA130CP, FA148CP, FA168C, FA168CPS, FA1220CV, FA1340C, FA1600C/CA/CB, FA1660C,
* Use the non-addressable mode with this (FA2000C) control (set to address 31).
** Use the addressable mode with these controls (addresses 00-30).
Notes: 1. Display backlighting is supported and timed out (see the control's instructions for details).
2.The FA570KP is required for certain advanced user functions (see the control's instructions for details).
ULC
For ULC installations, the FA1660C Series must be used with the FA570KP keypad.
GENERAL INFORMATIONWIRING AND INSTALLATION
remotekeypads and are intended for use with the controls
listed in the table above. Addresses are set via the keypad
keys (no DIP switches). The keypads are also compatible
with older control panels using the non-addressable mode
KEYPAD DISPLAYS AND LEDS
The keypads have the following features of the display:
Fixed
Display
Alpha
2, 3-digit
Identifier
Zone

First Alert Alarm Keypad Manual

FA220KP X 2-digit
FA570KP X 3-digit X
The following table shows the LEDs and their functions:
Red Lights when the system is armed in any mode
Green Lights when the system is 'ready' to be armed.
The keypads also feature programmable Special Function
keys. (See table below.) These keys may be programmed for
panic alarms or other special functions. See the control's

First Alert Fa260 Keypad Manual

instructions for details. The FA220KP uses the panic key
pairs only. Special Function keys must be held down
FA270KP/FA570KP FA220KP
B or ( & # ) ( & # )
The keypads can be surface mounted directly to a drywall, or to
1.To remove the case back, insert a small screwdriver
blade at a downward angle into Slot 1 and twist (the
right side pops up). Insert the screwdriver blade at a
downward angle into Slot 2 and twist (the left side pops
First Alert Keypad Manual
up). Insert the screwdriver blade into right side narrow
Slot 3 and twist. Separate the case back from upper case.
2.Route wiring from the control panel through the large
3.Mount the case back to a wall or electrical box.
connecting the keypad. Wire directly from the
keypad’s terminal block to the terminal block on the

First Alert Alarm Keypad Manual

control’s PC board. Wire functions are marked next to
terminals. See the control panel’s Installation Instructions
5.Reattach the keypad to its case back.
Special
Keys
Slot 2
Slot 1
ARMED
First Alert Keypad Manual
B
D

First Alert Professional Keypad Manual

FA270KP (shown) & FA570KP contain four Special Function Keys
(Special Function Keys not available on the FA220KP)

Related Products for First Alert FA220KP

Related Manuals for First Alert FA220KP

First Alert FA220KP: Frequently viewed Manuals